{"product_id":"victron-cyrix-li-charge-12-24v-230a-batteriekoppler-relais-batterieschutz-lithium","title":"Victron Cyrix Li-charge 12\/24V 230A battery coupler relay battery protection lithium","description":"\u003ch2\u003e Cyrix battery coupler Li-ion series: Li-Charge\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cb\u003eHow the Cyrix-Li-Charge works\u003c\/b\u003e\u003c\/p\u003e\n\n\n \u003cp\u003eThe Cyrix-Li-Charge connects a battery charger with a delay time of 3 seconds:\u003c\/p\u003e\n\n\n\u003cul\u003e\n\n\u003cli\u003e when the VE. Bus BMS \"Charge Disconnect\" output is high and\u003c\/li\u003e\n\n\u003cli\u003e if it measures 13.7 V (or 27.4) or more at its battery charger terminal and\u003c\/li\u003e\n\n\u003cli\u003e when it measures 2V or more at its battery terminal (the Cyrix remains open when not connected to the battery).\n\u003cp\u003e The Cyrix-Li-Charge switches off immediately when its control input reaches the \"free floating\" state (open circuit), indicates a cell overvoltage or a cell overtemperature.\u003cbr\u003e\n Generally, a cell overvoltage alarm will reset shortly after charging is stopped. The Cyrix will then reconnect the charger after a 3-second delay. After two attempts to reconnect the device at 3-second intervals, this delay time is extended to 10 minutes.\u003cbr\u003e \nWhenever the battery voltage falls below 13.5V (or 27V or 54V), the Cyrix switches off with a delay of 1 hour.\u003cbr\u003e\n Note 1: If the discharge current is 0 or there is only a very low discharge current, the Cyrix will not switch off shortly after the charger is switched off and\/or disconnected because the battery voltage remains above 13.5 V.\u003cbr\u003e\n Note 2: If the battery charger output immediately rises to 13.7V or more after the Cyrix has shut down, the Cyrix will restart with a delay of 3 seconds.\u003c\/p\u003e\n\n\n\u003cp\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cb\u003eProduct features\u003c\/b\u003e\u003c\/p\u003e\n\n\n\u003cul\u003e\n\n\u003cli\u003e Protects the battery from excessive discharge due to loads\u003c\/li\u003e\n\n\u003cli\u003e Continuous current: 230 A\u003c\/li\u003e\n\n\u003cli\u003e suitable for 12V and 24V systems, automatic detection\u003c\/li\u003e\n\n\u003cli\u003e intelligent control by microprocessor\u003cspan style=\"display: none;\"\u003e \u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55769337659737,"sku":"300-3197","price":147.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/9436\/8857\/files\/cyrix-li-chargejpg-322350.jpg?v=1761403235","url":"https:\/\/b2bshop.wattstunde.de\/en\/products\/victron-cyrix-li-charge-12-24v-230a-batteriekoppler-relais-batterieschutz-lithium","provider":"Wattstunde | B2B Shop","version":"1.0","type":"link"}